  https://www.phoenixcontact.com/pi/products/2902015 10/16/2018???page? 1 ?/? 5 repeater power supply?-?mini mcr-2-rpss-i-i-pt?-?2902015 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) 3-way repeater power supply with plug-in connection technology. hart-transparent, input signal 0(4)...20 ma, output signal 0(4)...20 ma. the device can be used in both isolator and repeater power supply operation. push-in connection technology product description the repeater power supply with plug-in connection technology supplies the transmitter in the field and electrically isolates the input signal from the output signal. hart data protocols can be transmitted bidirectionally. the device can be used in both isolator and repeater power supply operation. electrically isolated 0 ... 20?ma or 4 ... 20?ma standard analog signals are available on the input and output sides with a maximum output load of 600??. the measuring transducer supports fault monitoring and nfc communication. key commercial data packing unit 1 pc gtin gtin 4046356649544 technical data note utilization restriction emc: class a product, see manufacturer's declaration in the download area dimensions width 6.2 mm height 110.5 mm depth 120.5 mm ambient conditions ambient temperature (operation) -40 c ... 70 c ambient temperature (storage/transport) -40 c ... 85 c input data description of the input current input (sensor circuit) pwr+ pwrC + + C C C + passive in out fm 1 5 2 6 3 7 4 8 5 6 zone 2 2-wire 1 2 out iC pwrC pwr out + in iC sensor / field plc / dcs out i+ pwr in+ out iC ti+ pwr+ in i+ 4-wire u s 3 4 3-wire 1 4 3 pwr in+ out iC out i+ out iC out i+ in iC tiC ti+ active + C power i i out in power fm
https://www.phoenixcontact.com/pi/products/2902015 10/16/2018???page? 2 ?/? 5 repeater power supply?-?mini mcr-2-rpss-i-i-pt?-?2902015 technical data input data number of inputs 1 current input signal 4 ma ... 20 ma (repeater power supply and isolator operation) 0 ma ... 20 ma (isolator operation) input resistance current input approx. 68 (+ 0.7 v for test diode) transmitter supply voltage > 19.5 v output data output name current output number of outputs 1 current output signal 4 ma ... 20 ma (repeater power supply and isolator operation) 0 ma ... 20 ma (isolator operation) max. output current 24 ma load/output load current output 600 (at 20 ma) ripple < 20 mv pp (at 600 ) transmission behavior 1:1 to input signal power supply nominal supply voltage 24 v dc supply voltage range 9.6 v dc ... 30 v dc (the din rail bus connector (me 6,2 tbus-2 1,5/5-st-3,81 gn, order no. 2869728) can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en?60715)) typical current consumption 25 ma (at 24 v dc and in isolator operation) 50 ma (at 24 v dc and in repeater power supply operation) 55 ma (at 12 v dc and in isolator operation) 110 ma (at 12 v dc and in repeater power supply operation) power consumption 1400 mw (at i out = 20 ma, 9.6 v dc, 600 load) connection data connection method push-in connection single conductor/terminal point, solid, with ferrule, min. 0.14 mm2 single conductor/terminal point, solid, with ferrule, max. 2.5 mm2 single conductor/terminal point, solid, without ferrule, min. 0.14 mm2 single conductor/terminal point, solid, without ferrule, max. 2.5 mm2 conductor cross section flexible min. 0.14 mm2 conductor cross section flexible max. 2.5 mm2 min. awg conductor cross section, flexible 24 max. awg conductor cross section, flexible 12 stripping length 10 mm general no. of channels 1 maximum transmission error 0.05 % (of final value, at 4?ma?...?20?ma) 0.1 % (of final value, at 0?ma?...?20?ma) pwr+ pwrC + + C C C + passive in out fm 1 5 2 6 3 7 4 8 5 6 zone 2 2-wire 1 2 out iC pwrC pwr out + in iC sensor / field plc / dcs out i+ pwr in+ out iC ti+ pwr+ in i+ 4-wire u s 3 4 3-wire 1 4 3 pwr in+ out iC out i+ out iC out i+ in iC tiC ti+ active + C power i i out in power fm
https://www.phoenixcontact.com/pi/products/2902015 10/16/2018???page? 3 ?/? 5 repeater power supply?-?mini mcr-2-rpss-i-i-pt?-?2902015 technical data general maximum temperature coefficient 0.0075 %/k temperature coefficient, typical 0.0075 %/k limit frequency (3 db) > 1.75 khz (typ.) step response (10-90%) < 200 s (typ.) protective circuit transient protection electrical isolation reinforced insulation in accordance with iec 61010-1 overvoltage category ii degree of pollution 2 rated insulation voltage 300 v (effective) test voltage, input/output/supply 3 kv (50 hz, 1 min.) electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 noise immunity en 61000-6-2 when being exposed to interference, there may be minimal deviations. color gray housing material pbt mounting position any assembly instructions the t connector can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en 60715. conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t5 class i, zone 2, group iic t5 gl c, emc2 certificate of classification dnv gl 14445-15hh fire protection for rail vehicles (din en 45545-2) r22 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r23 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r24 hl 1 - hl 2 data communication (bypass) limit frequency (3 db) approx. 1.75 khz emc data designation electromagnetic rf field standards/regulations en 61000-4-3 designation fast transients (burst) standards/regulations en 61000-4-4 designation conducted interferences standards/regulations en?61000-4-6 standards and regulations electromagnetic compatibility conformance with emc directive pwr+ pwrC + + C C C + passive in out fm 1 5 2 6 3 7 4 8 5 6 zone 2 2-wire 1 2 out iC pwrC pwr out + in iC sensor / field plc / dcs out i+ pwr in+ out iC ti+ pwr+ in i+ 4-wire u s 3 4 3-wire 1 4 3 pwr in+ out iC out i+ out iC out i+ in iC tiC ti+ active + C power i i out in power fm
https://www.phoenixcontact.com/pi/products/2902015 10/16/2018???page? 4 ?/? 5 repeater power supply?-?mini mcr-2-rpss-i-i-pt?-?2902015 technical data standards and regulations noise emission en 61000-6-4 standards/regulations en 61000-4-2 designation electromagnetic rf field standards/regulations en 61000-4-3 en 61000-4-4 en 61000-4-5 designation conducted interferences standards/regulations en?61000-4-6 electrical isolation reinforced insulation in accordance with iec 61010-1 conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t5 class i, zone 2, group iic t5 gl c, emc2 fire protection for rail vehicles (din en 45545-2) r22 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r23 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r24 hl 1 - hl 2 environmental product compliance china rohs environmentally friendly use period = 50 for details about hazardous substances go to tab downloads, category manufacturer's declaration drawings block diagram pictogram approvals approvals pwr+ pwrC + + C C C + passive in out fm 1 5 2 6 3 7 4 8 5 6 zone 2 2-wire 1 2 out iC pwrC pwr out + in iC sensor / field plc / dcs out i+ pwr in+ out iC ti+ pwr+ in i+ 4-wire u s 3 4 3-wire 1 4 3 pwr in+ out iC out i+ out iC out i+ in iC tiC ti+ active + C power i i out in power fm
https://www.phoenixcontact.com/pi/products/2902015 10/16/2018???page? 5 ?/? 5 repeater power supply?-?mini mcr-2-rpss-i-i-pt?-?2902015 approvals approvals ul listed / cul listed / gl / culus listed ex approvals atex / ul listed / cul listed / culus listed approval details ul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 cul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 gl? ? ? http://exchange.dnv.com/tari/ ?14445-15 hh culus listed? ? ? ? phoenix contact 2018 ? - all rights reserved http://www.phoenixcontact.com phoenix contact gmbh & co. kg flachsmarktstr. 8 32825 blomberg germany tel. +49 5235 300 fax +49 5235 3 41200 http://www.phoenixcontact.com pwr+ pwrC + + C C C + passive in out fm 1 5 2 6 3 7 4 8 5 6 zone 2 2-wire 1 2 out iC pwrC pwr out + in iC sensor / field plc / dcs out i+ pwr in+ out iC ti+ pwr+ in i+ 4-wire u s 3 4 3-wire 1 4 3 pwr in+ out iC out i+ out iC out i+ in iC tiC ti+ active + C power i i out in power fm


▲Up To Search▲   

 
Price & Availability of 2902015

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X